Resultados 1 - 20 de 587
Filtrar
1.
Radiother Oncol ; 194: 110195, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38442840

RESUMEN

BACKGROUND AND PURPOSE: Partial breast irradiation (PBI)has beenthe Danish Breast Cancer Group(DBCG) standard for selected breast cancer patients since 2016 based onearlyresults from the DBCG PBI trial.During trial accrual, respiratory-gated radiotherapy was introduced in Denmark. This study aims to investigate the effect of respiratory-gating on mean heart dose (MHD). PATIENTS AND METHODS: From 2009 to 2016 the DBCG PBI trial included 230 patientswith left-sided breast cancer receiving external beam PBI, 40 Gy/15 fractions/3 weeks.Localization of the tumor bed on the planning CT scan, the use of respiratory-gating, coverage of the clinical target volume (CTV), and doses to organs at risk were collected. RESULTS: Respiratory-gating was used in 123 patients (53 %). In 176 patients (77 %) the tumor bed was in the upper and in 54 patients (23 %) in the lower breast quadrants. The median MHD was 0.37 Gy (interquartile range 0.26-0.57 Gy), 0.33 Gy (0.23-0.49 Gy) for respiratory-gating, and 0.49 Gy (0.31-0.70 Gy) for free breathing, p < 0.0001. MHD was < 1 Gy in 206 patients (90 %) and < 2 Gy in 221 patients (96 %). Respiratory-gating led to significantly lower MHD for upper-located, but not for lower-located tumor beds, however, all MHD were low irrespective of respiratory-gating. Respiratory-gating did not improve CTV coverage or lower lung doses. CONCLUSIONS: PBI ensured a low MHD for most patients. Adding respiratory-gating further reduced MHD for upper-located but not for lower-located tumor beds but did not influence target coverage or lung doses. Respiratory-gating is no longer DBCG standard for left-sided PBI.


Asunto(s)
Órganos en Riesgo , Humanos , Femenino , Persona de Mediana Edad , Órganos en Riesgo/efectos de la radiación , Dinamarca , Anciano , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/patología , Neoplasias de Mama Unilaterales/radioterapia , Dosificación Radioterapéutica , Corazón/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Adulto
2.
Magn Reson Imaging ; 107: 80-87, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38237694

RESUMEN

PURPOSE: To improve the scan efficiency of thoracic aorta vessel wall imaging using a self-gating (SG)-based motion correction scheme. MATERIALS AND METHODS: A slab-selective variable-flip-angle 3D turbo spin-echo (SPACE) sequence was modified to acquire SG signals and imaging data. Cartesian sampling with a tiny golden-step spiral profile ordering was used to obtain the imaging data during the systolic period, and then the image data were subsequently corrected based on the SG signals and binned to different respiratory cycles. Finally, respiratory artifacts were estimated from image-based registration of 3D undersampled respiratory bins that were reconstructed with L1 iterative self-consistent parallel imaging reconstruction (SPIRiT). This method was evaluated in 11 healthy volunteers and compared against conventional diaphragmatic navigator-gated acquisition to assess the feasibility of the proposed framework. RESULTS: Results showed that the proposed method achieved image quality comparable to that of conventional diaphragmatic navigator-gated acquisition with an average scan time of 4 min. The sharpness of the vessel wall and the definition of the liver boundary were in good agreement with the navigator-gated acquisition, which took approximately above 8.5 min depend on the respiratory rate. Further valuation of this technique in patients will be conducted to determine its clinical use.


Asunto(s)
Aorta Torácica , Técnicas de Imagen Sincronizada Respiratorias , Humanos , Aorta Torácica/diagnóstico por imagen , Imagenología Tridimensional/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Respiración , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos , Artefactos
3.
Med Phys ; 51(2): 1364-1382, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37427751

RESUMEN

BACKGROUND: The adoption of four-dimensional cone beam computed tomography (4DCBCT) for image-guided lung cancer radiotherapy is increasing, especially for hypofractionated treatments. However, the drawbacks of 4DCBCT include long scan times (∼240 s), inconsistent image quality, higher imaging dose than necessary, and streaking artifacts. With the emergence of linear accelerators that can acquire 4DCBCT scans in a short period of time (9.2 s) there is a need to examine the impact that these very fast gantry rotations have on 4DCBCT image quality. PURPOSE: This study investigates the impact of gantry velocity and angular separation between x-ray projections on image quality and its implication for fast low-dose 4DCBCT with emerging systems, such as the Varian Halcyon that provide fast gantry rotation and imaging. Large and uneven angular separation between x-ray projections is known to reduce 4DCBCT image quality through increased streaking artifacts. However, it is not known when angular separation starts degrading image quality. The study assesses the impact of constant and adaptive gantry velocity and determines the level when angular gaps impair image quality using state-of-the-art reconstruction methods. METHODS: This study considers fast low-dose 4DCBCT acquisitions (60-80 s, 200-projection scans). To assess the impact of adaptive gantry rotations, the angular position of x-ray projections from adaptive 4DCBCT acquisitions from a 30-patient clinical trial were analyzed (referred to as patient angular gaps). To assess the impact of angular gaps, variable and static angular gaps (20°, 30°, 40°) were introduced into evenly separated 200 projections (ideal angular separation). To simulate fast gantry rotations, which are on emerging linacs, constant gantry velocity acquisitions (9.2 s, 60 s, 120 s, 240 s) were simulated by sampling x-ray projections at constant intervals using the patient breathing traces from the ADAPT clinical trial (ACTRN12618001440213). The 4D Extended Cardiac-Torso (XCAT) digital phantom was used to simulate projections to remove patient-specific image quality variables. Image reconstruction was performed using Feldkamp-Davis-Kress (FDK), McKinnon-Bates (MKB), and Motion-Compensated-MKB (MCMKB) algorithms. Image quality was assessed using Structural Similarity-Index-Measure (SSIM), Contrast-to-Noise-Ratio (CNR), Signal-to-Noise-Ratio (SNR), Tissue-Interface-Width-Diaphragm (TIW-D), and Tissue-Interface-Width-Tumor (TIW-T). RESULTS: Patient angular gaps and variable angular gap reconstructions produced similar results to ideal angular separation reconstructions, while static angular gap reconstructions produced lower image quality metrics. For MCMKB-reconstructions, average patient angular gaps produced SSIM-0.98, CNR-13.6, SNR-34.8, TIW-D-1.5 mm, and TIW-T-2.0 mm, static angular gap 40° produced SSIM-0.92, CNR-6.8, SNR-6.7, TIW-D-5.7 mm, and TIW-T-5.9 mm and ideal produced SSIM-1.00, CNR-13.6, SNR-34.8, TIW-D-1.5 mm, and TIW-T-2.0 mm. All constant gantry velocity reconstructions produced lower image quality metrics than ideal angular separation reconstructions regardless of the acquisition time. Motion compensated reconstruction (MCMKB) produced the highest contrast images with low streaking artifacts. CONCLUSION: Very fast 4DCBCT scans can be acquired provided that the entire scan range is adaptively sampled, and motion-compensated reconstruction is performed. Importantly, the angular separation between x-ray projections within each individual respiratory bin had minimal effect on the image quality of fast low-dose 4DCBCT imaging. The results will assist the development of future 4DCBCT acquisition protocols that can now be achieved in very short time frames with emerging linear accelerators.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Técnicas de Imagen Sincronizada Respiratorias , Humanos , Tomografía Computarizada de Haz Cónico/métodos , Tomografía Computarizada Cuatridimensional/métodos , Fantasmas de Imagen , Relación Señal-Ruido , Técnicas de Imagen Sincronizada Respiratorias/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos
4.
Magn Reson Med ; 91(2): 600-614, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37849064

RESUMEN

PURPOSE: To develop a novel deep learning approach for 4D-MRI reconstruction, named Movienet, which exploits space-time-coil correlations and motion preservation instead of k-space data consistency, to accelerate the acquisition of golden-angle radial data and enable subsecond reconstruction times in dynamic MRI. METHODS: Movienet uses a U-net architecture with modified residual learning blocks that operate entirely in the image domain to remove aliasing artifacts and reconstruct an unaliased motion-resolved 4D image. Motion preservation is enforced by sorting the input image and reference for training in a linear motion order from expiration to inspiration. The input image was collected with a lower scan time than the reference XD-GRASP image used for training. Movienet is demonstrated for motion-resolved 4D MRI and motion-resistant 3D MRI of abdominal tumors on a therapeutic 1.5T MR-Linac (1.5-fold acquisition acceleration) and diagnostic 3T MRI scanners (2-fold and 2.25-fold acquisition acceleration for 4D and 3D, respectively). Image quality was evaluated quantitatively and qualitatively by expert clinical readers. RESULTS: The reconstruction time of Movienet was 0.69 s (4 motion states) and 0.75 s (10 motion states), which is substantially lower than iterative XD-GRASP and unrolled reconstruction networks. Movienet enables faster acquisition than XD-GRASP with similar overall image quality and improved suppression of streaking artifacts. CONCLUSION: Movienet accelerates data acquisition with respect to compressed sensing and reconstructs 4D images in less than 1 s, which would enable an efficient implementation of 4D MRI in a clinical setting for fast motion-resistant 3D anatomical imaging or motion-resolved 4D imaging.


Asunto(s)
Imagen por Resonancia Magnética , Técnicas de Imagen Sincronizada Respiratorias , Imagen por Resonancia Magnética/métodos , Imagenología Tridimensional/métodos , Movimiento (Física) , Aceleración , Técnicas de Imagen Sincronizada Respiratorias/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Respiración
5.
J Nucl Med Technol ; 51(1): 32-37, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36750380

RESUMEN

Respiration gating is used in PET to prevent image quality degradation due to respiratory effects. In this study, we evaluated a type of data-driven respiration gating for continuous bed motion, OncoFreeze AI, which was implemented to improve image quality and the accuracy of semiquantitative uptake values affected by respiratory motion. Methods: 18F-FDG PET/CT was performed on 32 patients with lung lesions. Two types of respiration-gated images (OncoFreeze AI with data-driven respiration gating, device-based amplitude-based OncoFreeze with elastic motion compensation) and ungated images (static) were reconstructed. For each image, we calculated SUV and metabolic tumor volume (MTV). The improvement rate (IR) from respiration gating and the contrast-to-noise ratio (CNR), which indicates the improvement in image noise, were also calculated for these indices. IR was also calculated for the upper and lower lobes of the lung. As OncoFreeze AI assumes the presence of respiratory motion, we examined quantitative accuracy in regions where respiratory motion was not present using a 68Ge cylinder phantom with known quantitative accuracy. Results: OncoFreeze and OncoFreeze AI showed similar values, with a significant increase in SUV and decrease in MTV compared with static reconstruction. OncoFreeze and OncoFreeze AI also showed similar values for IR and CNR. OncoFreeze AI increased SUVmax by an average of 18% and decreased MTV by an average of 25% compared with static reconstruction. From the IR results, both OncoFreeze and OncoFreeze AI showed a greater IR from static reconstruction in the lower lobe than in the upper lobe. OncoFreeze and OncoFreeze AI increased CNR by 17.9% and 18.0%, respectively, compared with static reconstruction. The quantitative accuracy of the 68Ge phantom, assuming a region of no respiratory motion, was almost equal for the static reconstruction and OncoFreeze AI. Conclusion: OncoFreeze AI improved the influence of respiratory motion in the assessment of lung lesion uptake to a level comparable to that of the previously launched OncoFreeze. OncoFreeze AI provides more accurate imaging with significantly larger SUVs and smaller MTVs than static reconstruction.


Asunto(s)
Neoplasias Pulmonares , Técnicas de Imagen Sincronizada Respiratorias , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Respiración , Tomografía de Emisión de Positrones/métodos , Pulmón , Movimiento (Física) , Fluorodesoxiglucosa F18 , Técnicas de Imagen Sincronizada Respiratorias/métodos
6.
Eur Radiol ; 33(5): 3366-3376, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36565352

RESUMEN

OBJECTIVES: This study aimed to investigate the performance of respiratory-gating imaging with reduced acquisition time using the total-body positron emission tomography/computed tomography (PET/CT) scanner. METHODS: Imaging data of 71 patients with suspect malignancies who underwent total-body 2-[18F]-fluoro-2-deoxy-D-glucose PET/CT for 15 min with respiration recorded were analyzed. For each examination, four reconstructions were performed: Ungated-15, using all coincidences; Ungated-5, using data of the first 5 min; Gated-15 using all coincidences but with respiratory gating; and Gated-6 using data of the first 6 min with respiratory gating. Lesions were quantified and image quality was evaluated; both were compared between the four image sets. RESULTS: A total of 390 lesions were found in the thorax and upper abdomen. Lesion detectability was significantly higher in gated-15 (97.2%) than in ungated-15 (93.6%, p = 0.001) and ungated-5 (92.3%, p = 0.001), but comparable to Gated-6 (95.9%, p = 0.993). A total of 131 lesions were selected for quantitative analyses. Lesions in Gated-15 presented significantly larger standardized uptake values, tumor-to-liver ratio, and tumor-to-blood ratio, but smaller metabolic tumor volume, compared to those in Ungated-15 and Ungated-5 (all p < 0.001). These differences were more obvious in small lesions and in lesions from sites other than mediastinum/retroperitoneum. However, these indices were not significantly different between Gated-15 and Gated-6. Higher, but acceptable, image noise was identified in gated images than in ungated images. CONCLUSIONS: Respiratory-gating imaging with reduced scanning time using the total-body PET/CT scanner is superior to ungated imaging and can be used in the clinic. KEY POINTS: • In PET imaging, respiratory gating can improve lesion presentation and detectability but requires longer imaging time. • This single-center study showed that the total-body PET scanner allows respiratory-gated imaging with reduced and clinically acceptable scanning time.


Asunto(s)
Neoplasias Hepáticas , Técnicas de Imagen Sincronizada Respiratorias , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Tomografía de Emisión de Positrones/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Desoxiglucosa , Fluorodesoxiglucosa F18
7.
J Cardiovasc Magn Reson ; 24(1): 47, 2022 08 11.
Artículo en Inglés | MEDLINE | ID: mdl-35948936

RESUMEN

BACKGROUND: Exercise cardiovascular magnetic resonance (Ex-CMR) is a promising stress imaging test for coronary artery disease (CAD). However, Ex-CMR requires accelerated imaging techniques that result in significant aliasing artifacts. Our goal was to develop and evaluate a free-breathing and electrocardiogram (ECG)-free real-time cine with deep learning (DL)-based radial acceleration for Ex-CMR. METHODS: A 3D (2D + time) convolutional neural network was implemented to suppress artifacts from aliased radial cine images. The network was trained using synthetic real-time radial cine images simulated using breath-hold, ECG-gated segmented Cartesian k-space data acquired at 3 T from 503 patients at rest. A prototype real-time radial sequence with acceleration rate = 12 was used to collect images with inline DL reconstruction. Performance was evaluated in 8 healthy subjects in whom only rest images were collected. Subsequently, 14 subjects (6 healthy and 8 patients with suspected CAD) were prospectively recruited for an Ex-CMR to evaluate image quality. At rest (n = 22), standard breath-hold ECG-gated Cartesian segmented cine and free-breathing ECG-free real-time radial cine images were acquired. During post-exercise stress (n = 14), only real-time radial cine images were acquired. Three readers evaluated residual artifact level in all collected images on a 4-point Likert scale (1-non-diagnostic, 2-severe, 3-moderate, 4-minimal). RESULTS: The DL model substantially suppressed artifacts in real-time radial cine images acquired at rest and during post-exercise stress. In real-time images at rest, 89.4% of scores were moderate to minimal. The mean score was 3.3 ± 0.7, representing increased (P < 0.001) artifacts compared to standard cine (3.9 ± 0.3). In real-time images during post-exercise stress, 84.6% of scores were moderate to minimal, and the mean artifact level score was 3.1 ± 0.6. Comparison of left-ventricular (LV) measures derived from standard and real-time cine at rest showed differences in LV end-diastolic volume (3.0 mL [- 11.7, 17.8], P = 0.320) that were not significantly different from zero. Differences in measures of LV end-systolic volume (7.0 mL [- 1.3, 15.3], P < 0.001) and LV ejection fraction (- 5.0% [- 11.1, 1.0], P < 0.001) were significant. Total inline reconstruction time of real-time radial images was 16.6 ms per frame. CONCLUSIONS: Our proof-of-concept study demonstrated the feasibility of inline real-time cine with DL-based radial acceleration for Ex-CMR.


Asunto(s)
Enfermedad de la Arteria Coronaria , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética , Técnicas de Imagen Sincronizada Respiratorias , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Aprendizaje Profundo , Prueba de Esfuerzo , Estudios de Factibilidad , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Reproducibilidad de los Resultados , Técnicas de Imagen Sincronizada Respiratorias/métodos
8.
Semin Nucl Med ; 52(6): 745-758, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35643531

RESUMEN

Positron emission tomography (PET) is an important imaging modality for personalizing clinical management of patients with lung cancer. In this regard, PET imaging is essential for adequate clinical staging and monitoring of treatment response in patients with lung cancer. The key advantage of PET over other radiological imaging modalities is its high sensitivity for the detection of pulmonary lesions, normal-sized metastatic hilar and/or mediastinal lymph nodes, and distant metastases. Furthermore, with increasing clinical evidence, the role of PET imaging for treatment selection, adaptation, early response monitoring and follow up in patients with lung cancer is being increasingly recognized. At the heart of PET imaging lies the ability to visualize and quantify numerous biological parameters that are responsible for treatment resistance. In order to ensure accurate and reproducible image quantification, harmonization of patient preparation and imaging protocols is essential. Additionally, there are several technical factors during PET scanning that have to be taken care of to safeguard image quality and quantitative accuracy. One of these factors is the occurrence of respiratory motion artifacts, which is a well-known factor that can significantly influence image quality and quantitative accuracy of PET images. If left uncorrected, respiratory motion artifacts can introduce uncertainties in diagnosis and staging, inaccuracies in definition of target volumes for radiation treatment planning, and hinder adequate monitoring of therapy response. Although many different respiratory gating techniques have been developed to correct PET images for respiratory motion artifacts, respiratory gating has traditionally not been widely adopted in clinical practice. This is due to the fact that these methods tend to be disruptive for the clinical workflow due the lengthening of image acquisition times, higher amounts of activity being administered to the patient, and the requirement to synchronize additional hardware with the scanner. Developments in respiratory gating techniques over the last years have resulted in considerable technical improvements. These newer respiratory gating techniques can operate directly on the acquired PET data without the use of additional hardware to trace respiratory motion and can be seamlessly applied into clinical routine. Furthermore, instead of only using a fraction of the acquired PET data newer methods have the ability to use all of the acquired PET data for image reconstruction, thereby improving image quality. The clinically added value of respiratory gating lies in improving image quality by reducing the amount of respiration-induced image blurring. This considerably improves the detection and characterization of small lesions, potentially improving early diagnosis and staging of patients with lung cancer. Furthermore, the incorporation of (4D) respiratory gated PET for radiotherapy purposes has shown to improve target volume definition through more accurate tracking of tumor motion. In addition, the effect of respiratory motion artifacts on widely used volumetric and uptake parameters in PET have been described. Although respiratory gating improves quantitative accuracy of PET images, the exact impact of these corrections on clinical management of patients with lung cancer often still needs to be determined.


Asunto(s)
Neoplasias Pulmonares , Técnicas de Imagen Sincronizada Respiratorias , Humanos , Tomografía de Emisión de Positrones/métodos , Artefactos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/terapia , Procesamiento de Imagen Asistido por Computador , Respiración , Técnicas de Imagen Sincronizada Respiratorias/métodos
9.
J Appl Clin Med Phys ; 23(5): e13619, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35481961

RESUMEN

Data driven respiratory gating (DDG) in positron emission tomography (PET) imaging extracts respiratory waveforms from the acquired PET data obviating the need for dedicated external devices. DDG performance, however, degrades with decreasing detected number of coincidence counts. In this paper, we assess the clinical impact of reducing injected activity on a new DDG algorithm designed for PET data acquired with continuous bed motion (CBM_DDG) by evaluating CBM_DDG waveforms, tumor quantification, and physician's perception of motion blur in resultant images. Forty patients were imaged on a Siemens mCT scanner in CBM mode. Reduced injected activity was simulated by generating list mode datasets with 50% and 25% of the original data (100%). CBM_DDG waveforms were compared to that of the original data over the range between the aortic arch and the center of the right kidney using the Pearson correlation coefficient (PCC). Tumor quantification was assessed by comparing the maximum standardized uptake value (SUVmax) and peak SUV (SUVpeak) of reconstructed images from the various list mode datasets using elastic motion deblurring (EMDB) reconstruction. Perceived motion blur was assessed by three radiologists of one lesion per patient on a continuous scale from no motion blur (0) to significant motion blur (3). The mean PCC of the 50% and 25% dataset waveforms was 0.74 ± 0.18 and 0.59 ± 0.25, respectively. In comparison to the 100% datasets, the mean SUVmax increased by 2.25% (p = 0.11) for the 50% datasets and by 3.91% (p = 0.16) for the 25% datasets, while SUVpeak changes were within ±0.25%. Radiologist evaluations of motion blur showed negligible changes with average values of 0.21, 0.3, and 0.28 for the 100%, 50%, and 25% datasets. Decreased injected activities degrades the resultant CBM_DDG respiratory waveforms; however this decrease has minimal impact on quantification and perceived image motion blur.


Asunto(s)
Neoplasias , Técnicas de Imagen Sincronizada Respiratorias , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Movimiento (Física) , Neoplasias/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos
10.
Phys Med Biol ; 67(8)2022 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-35313286

RESUMEN

Objective. Data-driven gating (DDG) can address patient motion issues and enhance PET quantification but suffers from increased image noise from utilization of <100% of PET data. Misregistration between DDG-PET and CT may also occur, altering the potential benefits of gating. Here, the effects of PET acquisition time and CT misregistration were assessed with a combined DDG-PET/DDG-CT technique.Approach. In the primary PET bed with lesions of interest and likely respiratory motion effects, PET acquisition time was extended to 12 min and a low-dose cine CT was acquired to enable DDG-CT. Retrospective reconstructions were created for both non-gated (NG) and DDG-PET using 30 s to 12 min of PET data. Both the standard helical CT and DDG-CT were used for attenuation correction of DDG-PET data. SUVmax, SUVpeak, and CNR were compared for 45 lesions in the liver and lung from 27 cases.Main results. For both NG-PET (p= 0.0041) and DDG-PET (p= 0.0028), only the 30 s acquisition time showed clear SUVmaxbias relative to the 3 min clinical standard. SUVpeakshowed no bias at any change in acquisition time. DDG-PET alone increased SUVmaxby 15 ± 20% (p< 0.0001), then was increased further by an additional 15 ± 29% (p= 0.0007) with DDG-PET/CT. Both 3 min and 6 min DDG-PET had lesion CNR statistically equivalent to 3 min NG-PET, but then increased at 12 min by 28 ± 48% (p= 0.0022). DDG-PET/CT at 6 min had comparable counts to 3 min NG-PET, but significantly increased CNR by 39 ± 46% (p< 0.0001).Significance. 50% counts DDG-PET did not lead to inaccurate or biased SUV-increased SUV resulted from gating. Improved registration from DDG-CT was equally as important as motion correction with DDG-PET for increasing SUV in DDG-PET/CT. Lesion detectability could be significantly improved when DDG-PET used equivalent counts to NG-PET, but only when combined with DDG-CT in DDG-PET/CT.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Técnicas de Imagen Sincronizada Respiratorias , Humanos , Movimiento (Física) , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
11.
Br J Radiol ; 94(1126): 20201350, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34520673

RESUMEN

OBJECTIVES: To evaluate the impact of fully automatic motion correction by data-driven respiratory gating (DDG) on positron emission tomography (PET) image quality, lesion detection and patient management. MATERIALS AND METHODS: A total of 149 patients undergoing PET/CT for cancer (re-)staging were retrospectively included. Patients underwent a PET/CT on a digital detector scanner and for every patient a PET data set where DDG was enabled (PETDDG) and as well as where DDG was not enabled (PETnonDDG) was reconstructed. All PET data sets were evaluated by two readers which rated the general image quality, motion effects and organ contours. Further, both readers reviewed all scans on a case-by-case basis and evaluated the impact of PETDDG on additional apparent lesion, change of report, and change of management. RESULTS: In 85% (n = 126) of the patients, at least one bed position was acquired using DDG, resulting in mean scan time increase of 4:37 min per patient in the whole study cohort (n = 149). General image quality was not rated differently for PETnonDDG and PETDDG images (p = 1.000) while motion effects (i.e. indicating general blurring) was rated significantly lower in PETDDG images and organ contours, including liver and spleen, were rated significantly sharper using PETDDG as compared to PETnonDDG (all p < 0.001). In 27% of patients, PETDDG resulted in a change of the report and in a total of 12 cases (8%), PETDDG resulted in a change of further clinical management. CONCLUSION: Deviceless DDG provided reliable fully automatic motion correction in clinical routine and increased lesion detectability and changed management in a considerable number of patients. ADVANCES IN KNOWLEDGE: DDG enables PET/CT with respiratory gating to be used routinely in clinical practice without external gating equipment needed.


Asunto(s)
Neoplasias/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Estadificación de Neoplasias , Neoplasias/patología , Neoplasias/terapia , Estudios Retrospectivos
12.
PLoS One ; 16(1): e0245878, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33503053

RESUMEN

Respiratory-gated four-dimensional phase-contrast vastly undersampled isotropic projection reconstruction (4D PC-VIPR) is magnetic resonance (MR) imaging technique that enables analysis of vascular morphology and hemodynamics in a single examination using cardiac phase resolved 3D phase-contrast magnetic resonance imaging. The present study aimed to assess the usefulness of 4D PC-VIPR for the superior mesenteric artery (SMA) flowmetry before and after flow increase was induced by the herbal medicine Daikenchuto (TJ-100) by comparing it with Doppler ultrasound (DUS) as a current standard. Twenty healthy volunteers were enrolled in this prospective single-arm study. The peak cross-sectionally averaged velocity was measured by 4D PC-VIPR, peak velocity was measured by DUS, and flow volume (FV) of SMA and aorta were measured by 4D PC-VIPR and DUS 25 min before and after the peroral administration of TJ-100. The peak cross-sectionally averaged velocity, peak velocity, and FV of SMA measured by 4D PC-VIPR and DUS significantly increased after administration of TJ-100 (4D PC-VIPR: the peak cross-sectionally averaged velocity; p = 0.004, FV; p = 0.035, DUS: the peak velocity; p = 0.003, FV; p = 0.010). Furthermore, 4D PC-VIPR can analyze multiple blood vessels simultaneously. The ratio of the SMA FV to the aorta, before and after oral administration on the 4D PC-VIPR test also increased (p = 0.015). The rate of change assessed by 4D PC-VIPR and DUS were significantly correlated (the peak cross-sectionally averaged velocity and peak velocity: r = 0.650; p = 0.005, FV: r = 0.659; p = 0.004). Retrospective 4D PC-VIPR was a useful modality for morphological and hemodynamic analysis of SMA.


Asunto(s)
Imagen por Resonancia Magnética/normas , Arterias Mesentéricas/diagnóstico por imagen , Extractos Vegetales/farmacología , Técnicas de Imagen Sincronizada Respiratorias/normas , Ultrasonografía Doppler/normas , Adulto , Velocidad del Flujo Sanguíneo , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Arterias Mesentéricas/efectos de los fármacos , Arterias Mesentéricas/fisiología , Panax , Técnicas de Imagen Sincronizada Respiratorias/métodos , Ultrasonografía Doppler/métodos , Zanthoxylum , Zingiberaceae
13.
Phys Med Biol ; 65(24): 245020, 2020 12 11.
Artículo en Inglés | MEDLINE | ID: mdl-32590382

RESUMEN

Motion compensation can eliminate inconsistencies of respiratory movement during image acquisitions for precise vascular reconstruction in the clinical diagnosis of vascular disease from x-ray angiographic image sequences. In x-ray-based vascular interventional therapy, motion modeling can simulate the process of organ deformation driven by motion signals to display a dynamic organ on angiograms without contrast agent injection. Automatic respiratory signal estimation from x-ray angiographic image sequences is essential for motion compensation and modeling. The effects of respiratory motion, cardiac impulses, and tremors on structures in the chest and abdomen bring difficulty in extracting accurate respiratory signals individually. In this study, an end-to-end deep learning framework based on a motion-flow-guided recurrent network is proposed to address the aforementioned problem. The proposed method utilizes a convolutional neural network to learn the spatial features of every single frame, and a recurrent neural network to learn the temporal features of the entire sequence. The combination of the two networks can effectively analyze the image sequence to realize respiratory signal estimation. In addition, the motion-flow between consecutive frames is introduced to provide a dynamic constraint of spatial features, which enables the recurrent network to learn better temporal features from dynamic spatial features than from static spatial features. We demonstrate the advantages of our approach on designed datasets which contain coronary and hepatic angiographic sequences with diaphragm structures, and coronary angiographic sequences without diaphragm structures. Our method improves over state-of-the-art manifold-learning-based methods by 85.7%, 81.5% and 75.3% in respiratory signal accuracy metric on these datasets. The results demonstrate that the proposed method can effectively estimate respiratory signals from multiple motion patterns.


Asunto(s)
Algoritmos , Angiografía Coronaria/métodos , Arteria Hepática/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Movimiento , Redes Neurales de la Computación , Técnicas de Imagen Sincronizada Respiratorias/métodos , Humanos , Respiración , Rayos X
14.
J Nucl Med Technol ; 48(2): 126-135, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32499322

RESUMEN

The purpose of this document is to assist nuclear medicine practitioners in recommending, performing, interpreting, and reporting the results of gated equilibrium radionuclide angiocardiography (ERNA).


Asunto(s)
Angiografía/métodos , Medicina Nuclear , Guías de Práctica Clínica como Asunto , Cintigrafía/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Sociedades Científicas , Europa (Continente) , Humanos
15.
Phys Med Biol ; 65(16): 165007, 2020 08 19.
Artículo en Inglés | MEDLINE | ID: mdl-32454466

RESUMEN

It is important to measure the respiratory cycle in positron emission tomography (PET) to enhance the contrast of the tumor as well as the accuracy of its localization in organs such as the lung and liver. Several types of data-driven respiratory gating methods, such as center of mass and principal component analysis, have been developed to directly measure the breathing cycle from PET images and listmode data. However, the breathing cycle is still hard to detect in low signal-to-noise ratio (SNR) data, particularly in low dose PET/CT scans. To address this issue, a time-of-flight (TOF) PET is currently utilized for the data-driven respiratory gating because of its higher SNR and better localization of the region of interest. To further improve the accuracy of respiratory gating with TOF information, we propose an accurate data-driven respiratory gating method, which retrospectively derives the respiratory signal using a localized sensing method based on a diaphragm mask in TOF PET data. To assess the accuracy of the proposed method, the performance is evaluated with three patient datasets, and a pressure-belt signal as the ground truth is compared. In our experiments, we validate that the respiratory signal using the proposed data-driven gating method is well matched to the pressure-belt respiratory signal with less than 5% peak time errors and over 80% trace correlations. Based on gated signals, the respiratory-gated image of the proposed method provides more clear edges of organs compared to images using conventional non-TOF methods. Therefore, we demonstrate that the proposed method can achieve improvements for the accuracy of gating signals and image quality.


Asunto(s)
Diafragma/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Humanos , Respiración , Estudios Retrospectivos , Relación Señal-Ruido
16.
Eur Radiol ; 30(9): 5130-5138, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32333146

RESUMEN

OBJECTIVES: To evaluate the feasibility and image quality of respiratory motion-resolved 4D zero echo time (ZTE) lung MRI compared with that of 3D ZTE. METHODS: Our institutional review board approved this study. Twenty-one patients underwent lung scans using 3D ZTE and 4D ZTE sequences via prospective and retrospective soft gating techniques, respectively. Image qualities of 3D ZTE and 4D ZTE at end-expiration were compared through objective and subjective assessments. The quality of end-expiratory images of 3D ZTE and 4D ZTE of the two groups with different lung functions was also compared. RESULTS: Images were successfully acquired in all patients without any adverse events. Signal-to-noise ratios (SNRs) of lung parenchyma and thoracic structures were significantly (all p < 0.001) higher in 4D ZTE. Contrast-to-noise ratios (CNRs) of peripheral bronchi, peripheral pulmonary vessels, and nodules or masses were significantly (all p < 0.001) higher in 4D ZTE. The subjective image quality assessed by two independent radiologists showed that intrapulmonary structures, noise and artifacts, and overall acceptability were superior in 4D ZTE (all p < 0.001). Image qualities of groups with normal and low lung functions differed significantly (all p < 0.05) in 3D ZTE, but not in 4D ZTE. The mean acquisition time was 136 s (127-143 s) in 3D ZTE and 325 s (308-352 s) in 4D ZTE. CONCLUSIONS: Respiratory motion-resolved 4D ZTE lung imaging was feasible as part of routine chest MRI. The 4D ZTE provides motion-robust lung parenchymal images with better SNR and CNR than the 3D ZTE, regardless of patients' lung function. KEY POINTS: • ZTE MRI captures rapidly decaying transverse magnetization in the lung parenchyma. • 4D ZTE provides motion-robust lung parenchymal images with better SNR and CNR compared with 3D ZTE. • Compared with 3D ZTE, the image quality of 4D ZTE lung MRI was affected less by patients' lung function and respiratory performance.


Asunto(s)
Imagenología Tridimensional/métodos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Estudios Prospectivos , Respiración , Estudios Retrospectivos , Relación Señal-Ruido , Tórax/diagnóstico por imagen , Adulto Joven
17.
J Nucl Med ; 61(11): 1678-1683, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32245898

RESUMEN

A data-driven method for respiratory gating in PET has recently been commercially developed. We sought to compare the performance of the algorithm with an external, device-based system for oncologic 18F-FDG PET/CT imaging. Methods: In total, 144 whole-body 18F-FDG PET/CT examinations were acquired, with a respiratory gating waveform recorded by an external, device-based respiratory gating system. In each examination, 2 of the bed positions covering the liver and lung bases were acquired with a duration of 6 min. Quiescent-period gating retaining approximately 50% of coincidences was then able to produce images with an effective duration of 3 min for these 2 bed positions, matching the other bed positions. For each examination, 4 reconstructions were performed and compared: data-driven gating (DDG) (we use the term DDG-retro to distinguish that we did not use the real-time R-threshold-based application of DDG that is available within the manufacturer's product), external device-based gating (real-time position management (RPM)-gated), no gating but using only the first 3 min of data (ungated-matched), and no gating retaining all coincidences (ungated-full). Lesions in the images were quantified and image quality scored by a radiologist who was masked to the method of data processing. Results: Compared with the other reconstruction options, DDG-retro increased the SUVmax and decreased the threshold-defined lesion volume. Compared with RPM-gated, DDG-retro gave an average increase in SUVmax of 0.66 ± 0.1 g/mL (n = 87, P < 0.0005). Although the results from the masked image evaluation were most commonly equivalent, DDG-retro was preferred over RPM-gated in 13% of examinations, whereas the opposite occurred in just 2% of examinations. This was a significant preference for DDG-retro (P = 0.008, n = 121). Liver lesions were identified in 23 examinations. Considering this subset of data, DDG-retro was ranked superior to ungated-full in 6 of 23 (26%) cases. Gated reconstruction using the external device failed in 16% of examinations, whereas DDG-retro always provided a clinically acceptable image. Conclusion: In this clinical evaluation, DDG-retro provided performance superior to that of the external device-based system. For most examinations the performance was equivalent, but DDG-retro had superior performance in 13% of examinations, leading to a significant preference overall.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Algoritmos , Humanos
18.
Curr Radiopharm ; 13(3): 218-227, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32183685

RESUMEN

BACKGROUND: Motion artifacts related to the patient's breathing can be the cause of underestimation of the lesion uptake and can lead to missing of small lung lesions. The respiratory gating (RG) technology has demonstrated a significant increase in image quality. OBJECTIVE: The aim of this paper was to evaluate the advantages of RG technique on PET/CT performance in lung lesions. The impact of 4D-PET/CT on diagnosis (metabolic characterization), staging and re-staging lung cancer was also assessed, including its application for radiotherapy planning. Finally, new technologies for respiratory motion management were also discussed. METHODS: A comprehensive electronic search of the literature was performed by using Medline database (PubMed) searching "PET/CT", "gated" and "lung". Original articles, review articles, and editorials published in the last 10 years were selected, included and critically reviewed in order to select relevant articles. RESULTS: Many papers compared Standardized Uptake Value (SUV) in gated and ungated PET studies showing an increase in SUV of gated images, particularly for the small lesions located in medium and lower lung. In addition, other features as Metabolic Tumor Volume (MTV), Total Lesion Glycolysis (TLG) and textural-features presented differences when obtained from gated and ungated PET acquisitions. Besides the increase in quantification, gating techniques can determine an increase in the diagnostic accuracy of PET/CT. Gated PET/CT was evaluated for lung cancer staging, therapy response assessment and for radiation therapy planning. CONCLUSION: New technologies able to track the motion of organs lesion directly from raw PET data, can reduce or definitively solve problems (i.e.: extended acquisition time, radiation exposure) currently limiting the use of gated PET/CT in clinical routine.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Artefactos , Humanos , Neoplasias Pulmonares/patología , Estadificación de Neoplasias , Radiofármacos , Planificación de la Radioterapia Asistida por Computador , Carga Tumoral
19.
AJR Am J Roentgenol ; 214(5): 1042-1053, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32023117

RESUMEN

OBJECTIVE. The purpose of this article is to review established and emerging methods for reducing motion artifacts in pediatric abdominal MRI. CONCLUSION. Clearly understanding the strengths and limitations of motion reduction methods can enable practitioners of pediatric abdominal MRI to select and combine the appropriate techniques and potentially reduce the need for sedation and anesthesia.


Asunto(s)
Abdomen/diagnóstico por imagen , Artefactos , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Niño , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Movimiento (Física)
20.
J Nucl Med ; 61(10): 1520-1527, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32060218

RESUMEN

Respiratory gating is the standard to prevent respiration effects from degrading image quality in PET. Data-driven gating (DDG) using signals derived from PET raw data is a promising alternative to gating approaches requiring additional hardware (e.g., pressure-sensitive belt gating [BG]). However, continuous-bed-motion (CBM) scans require dedicated DDG approaches for axially extended PET, compared with DDG for conventional step-and-shoot scans. In this study, a CBM-capable DDG algorithm was investigated in a clinical cohort and compared with BG using optimally gated (OG) and fully motion-corrected (elastic motion correction [EMOCO]) reconstructions. Methods: Fifty-six patients with suspected malignancies in the thorax or abdomen underwent whole-body 18F-FDG CBM PET/CT using DDG and BG. Correlation analyses were performed on both gating signals. Besides static reconstructions, OG and EMOCO reconstructions were used for BG and DDG. The metabolic volume, SUVmax, and SUVmean of lesions were compared among the reconstructions. Additionally, the quality of lesion delineation in the different PET reconstructions was independently evaluated by 3 experts. Results: The global correlation coefficient between BG and DDG signals was 0.48 ± 0.11, peaking at 0.89 ± 0.07 when scanning the kidney and liver region. In total, 196 lesions were analyzed. SUV measurements were significantly higher in BG-OG, DDG-OG, BG-EMOCO, and DDG-EMOCO than in static images (P < 0.001; median SUVmax: static, 14.3 ± 13.4; BG-EMOCO, 19.8 ± 15.7; DDG-EMOCO, 20.5 ± 15.6; BG-OG, 19.6 ± 17.1; and DDG-OG, 18.9 ± 16.6). No significant differences between BG-OG and DDG-OG or between BG-EMOCO and DDG-EMOCO were found. Visual lesion delineation was significantly better in BG-EMOCO and DDG-EMOCO than in static reconstructions (P < 0.001); no significant difference was found when comparing BG and DDG for either EMOCO or OG reconstruction. Conclusion: DDG-based motion compensation of CBM PET acquisitions outperforms static reconstructions, delivering qualities comparable to BG approaches. The new algorithm may be a valuable alternative for CBM PET systems.


Asunto(s)
Neoplasias/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Técnicas de Imagen Sincronizada Respiratorias/métodos , Imagen de Cuerpo Entero/métodos , Algoritmos , Humanos , Movimiento (Física)